The Pfizer network cut energy cost and emissions with virtual metering, unlocking over $8M a year and accelerating its Net Zero path. At Grange Castle, more than €500K in capex was avoided and ISO 50001 was achieved.
Read the case study →
This AI assistant may occasionally provide inaccurate or incomplete information.
By continuing, I agree to Ever.ag's privacy policy
Prefer a classic search? Go to search
Virtual Metering shows where water, air, gas, electricity, and steam (WAGES) are used, down to the machine and batch, so you can reduce operating costs and carbon.
Virtual metering uses the data your plant already collects, such as existing meters, PLC and SCADA signals, and historian records, to calculate how much water, air, gas, electricity, and steam each machine, process, and batch uses. No new meters or plant downtime required.
Integrate with your plant historians and automation systems. No new meters and no plant downtime.
Virtual metering shows where utilities are used by asset, line, and batch.
Spot abnormal consumption, underperforming equipment, and opportunities to reduce waste.
Prioritize improvements, track results, and verify the savings.

The Pfizer network cut energy cost and emissions with virtual metering, unlocking over $8M a year and accelerating its Net Zero path. At Grange Castle, more than €500K in capex was avoided and ISO 50001 was achieved.
Read the case study →
Diageo saved 18M gallons of water a year at its Plainfield Distillery alone, driving deployment across all its North American distilleries.

Deployed across every US and Australian plant, including the world's largest yogurt facility. Capex came in more than 60% below the alternatives, and its VP of Engineering credits it with hundreds of thousands saved on infrastructure.
Read the case study →Energy Manager helps manufacturers reduce utility consumption and operating costs using existing plant data and advanced analytics.
Identify opportunities to lower energy consumption and operating expenses.
Minimize the need for additional physical metering.
Identify savings opportunities using historical plant data.
Understand energy consumption by process and production activity.
Quantify savings opportunities and track results.
It also supports sustainability goals by reducing resource consumption and waste.
Your estimate
Enter your work email to see an illustrative savings range based on your numbers.
The full estimate on the calculator page also counts avoided metering capex, payback, and CO2e avoided.
View full calculator →Modeled estimate, not a guarantee. Actual savings depend on plant operations, data quality, and the measures implemented.
Rank every machine and process by consumption and cost.
Measure before-and-after savings for every project.
Link energy to production output by line and product.
Tie emissions data to real equipment.
Baselines, energy performance indicators, and tracking in one place. Pfizer Grange Castle achieved ISO 50001.
Benchmark sites and spread best practice across them.
Common loads across industries: CIP, steam, chilled water, compressed air, HVAC, and cooling towers.
HVAC and clean-room programs and multi-site Net Zero goals, without disturbing validated processes.
Refrigeration, CIP, pasteurization, and steam. Energy cost per unit for every product line.
Steam-heavy distillation and fermentation, mapped by batch and by still.
Boilers, reactors, and pumps. Spot drift in energy intensity before it shows up on the bill.
Compressed air, paint shops, and ovens. Find leaks and idle-time waste across lines.
Molding, extrusion, and chillers. Energy per part and per shift, machine by machine.
| Capability | Energy Manager | Physical Sub-metering |
|---|---|---|
| Meters | Virtual plus existing | Installing meter per asset |
| Plant Downtime | None | Required for install |
| Historic Data | Backfilled | Starts at install |
| Time to First Insight | Weeks | Months |
| Per Meter Cost Per Site | $10s | $1,000s |
Energy Manager uses your existing metering and automation infrastructure as its primary data source, such as Rockwell, AVEVA PI, DCS and PLC systems (DeltaV, Honeywell, Schneider), BMS, and SCADA. No new metering hardware is required.
Most deployments take about 12 weeks, with no plant downtime. Because Energy Manager works from your existing historian and control data, and backfills energy information from your historized data, customers like Chobani identified savings within weeks of starting.
After commissioning and tuning, virtual meters typically come within 3% to 5% of a calibrated physical meter, a result we validated with pharmaceutical customers who ran real and virtual meters in parallel. A physical meter will usually be more accurate at its single point, but it typically costs $5K to $25K per point once installation and downtime are included. Virtual meters provide broad visibility first, then help you pinpoint the few physical meter locations that will deliver the greatest value, if you choose to install them.
Security is built into Energy Manager from the start. It connects only to the systems and data sources your IT and OT teams approve, and we review your security requirements during design and implementation before any connection is made. Our security program includes SOC 2-compliant controls, continuous vulnerability monitoring, and security reviews of all new code before release. We address identified issues promptly to help ensure your production data remains protected and your operations keep running.
Energy Manager is a subscription, scoped to the plants, utilities, and equipment you want covered. Because scope varies, we start with an energy assessment or a conversation about your plant data, then provide a quote.
Energy Manager serves any plant that runs on water, air, gas, electricity, or steam. Customers include Pfizer in biopharma, Chobani in food and beverage, and Diageo in distilling, and the same approach applies to chemicals, automotive and discrete manufacturing, and plastics and packaging.
No. Energy Manager is monitoring and analytics. It turns data from your existing systems into energy and cost information, and it does not replace your control systems. However, its mimics and dashboards provide live utility performance metrics and status information.
An energy assessment is a scoped first step in which our energy engineers work with your existing plant data to show where utilities are used and to quantify the savings opportunity, before you decide on wider deployment.
Start with an energy assessment on your own plant data. Our energy engineers help you go from data to savings.
Estimate your savings first →